ACG Logo
Autoclave Selector Index: Initial Cure Temperature Selector
Go Back
Please select the option which reflects the intended Initial Cure temperature for your product.
Initial Cure 50 (122) - End Use? Initial Cure 60 (140) - End Use? High Temperature Tooling

ACG's LTM10 and 210 series prepreg tooling systems offer high temperature end performance after low temperature initial cure, minimizing dimensional and angular changes and providing cost effective materials for master model construction.  Step ahead cure technology, with temperature stability developing ahead of cure temperature, allows high temperature performance to be achieved after post cure without loss of stability or dimensional tolerance.

Product selection must balance initial cure temperature and product outlife to ensure that lay-up time and master model temperature resistance are not compromised.

Prepreg Description

All LTM® prepregs are designated by a reference code as shown in the example below:

LTM12 / CF 0100 T
Up Arrow   Up Arrow Up Arrow Up Arrow
Resin System   Fibre Type Weave Style Denotes Tooling Grade - Specific fibre and weaving sources tested and approved for use in tool construction.

Extended outlife systems (click here to refer to the vacuum section)
• LTM310 Series outlife 21 to 30 days  
• 65°C (149°F) initial cure
• Maximum operating temperature 150 to 180°C (302 to 356°F)

Note: LTM10 and 210 series prepregs can be used under vacuum moulding conditions with a gel coat (click here to refer to the vacuum section).